DSC MAXSYS PC4820 Access Control Expansion Cabinet (2 Doors)

 $613.85 
Quantity:
DSC MAXSYS PC4820 Access Control Expansion Cabinet (2 Doors)

The PC4820 enhances the value of Maxsys by tightly integrating access control with Maxsys security and fire features. Providing 2 door access control, the PC4820 provides the ultimate in security system ease of use and maximum reduction of false alarms by allowing users to arm/disarm the security system while locking/unlocking the door from outside of the protected space.

Up to 16 PC4820 modules, controlling up to 32 doors, can be added to PC4010/4020 systems via the systems 4-wire Combus using standard, unshielded station wire up to 1,000ft (305m) from the control panel.

Features:

  • Includes metal enclosure
  • System Capacities: PC4010, PC4010CF, PC4020, and PC4020CF control panels; up to 16 PC4820 modules for up to 32 readers; 1,000 access cards.
  • Supported Readers: Polaris mag-stripe readers & cards, Shadow Prox proximity readers & cards, HID proximity readers & cards, Wiegand standard 26 bit; readers may be located up to 500ft. (152m) from PC4820, shielded cable always required.
  • 2 reader access control: 2 single reader doors or 1 door with entry/exit readers
  • Flexible card holder privileges: assign individual access privileges by door & by schedule, define user rights to permit arming & disarming by partition, designate “privileged” users who are authorized to validate access for “wait for privileged” users (guardian function)
  • Full stand-alone operation, complete card database & all programming is maintained in the PC4820’s non-volatile memory: each module has its own time clock; in the event of power failure or PC4010/4020 system failure, each PC4820 access control module is capable of full operation on battery as a stand-alone access control system
  • Arm/disarm partitions & postpone autoarm by access card or access card and code, from outside the protected space: arm & disarm from outside the protected partition to reduce false alarms caused by entry/exit errors. To disarm, use a valid* card on a reader assigned to a partition to unlock the door and disarm the partition when the user opens the door. To arm, ensure that partition is secure, then use a valid* card on reader and activate the ARM input (usually a supervised pushbutton). To postpone autoarm, while a partition’s autoarm pre-alert is sounding, use a valid* card on any reader assigned to the partition and activate the POST input (usually a supervised pushbutton). Autoarm will be postponed for up to 255 minutes, after which the system will attempt to autoarm again. *(a valid card is one which has been programmed to perform the indicated function on a specified partition during a valid time for that user.)
  • 64 access levels
  • 99 seven-day schedules, 4 time intervals per schedule
  • 4 two year holiday groups, 730 holidays
  • Individual door-unlock schedules
  • Automatic switching between daylight savings & standard time
  • Program via keypad, or via computer with DLS-2 downloading software
  • Non-volatile RAM, does not lose programming when powered down
  • Fully supervised by PC4010(CF) & PC4020(CF) control panels for: lock trouble, reader low power trouble, low battery, AC failure, tamper, auxiliary power trouble
  • Door held open activates reader sounder
  • Door forced open activates reader sounder and sets off zone alarm if system is armed
  • Battery required: 12volt, 7.0Ah rechargeable lead acid
  • Transformer required, 16.5VAC, 40VA
  • 1.5A regulated power supply: provides auxiliary power, and power to readers and door locks, provides electronic shutdown protection of battery, auxiliary output, reader power supplies, and lock device power output
  • Power capacity per door: reader: 125mA max. @ 5VDC or 125mA max. @ 12VDC, lock: 250mA max. @ 12VDC (Can be set to fail-safe or fail-secure modes. 12VDC, low current, continuous duty electric strikes recommended. Check local regulations before installing electric locks)
  • Auxiliary power 125mA max. @ 12VDC
  • 4 wire QUAD connection to COMBUS, up to 1,000ft (305m) from PC4010/CF & PC4020/CF control panels
  • 2 low current outputs per door: open collector outputs switched to ground 25mA max.: LED, to reader LED input; BUZ, to reader piezo or other local door sounder
  • 4 inputs per door:
    • DOOR: door-contact input; supervised alarm zone (N/C loop, single or double EOL resistors); program to any partition and alarm zone from zones 9 to 64 on PC4010(CF) panels and zones 17 to 128 on PC4020(CF) panels; program as standard or auxiliary delay zone types
    • REX: request-to-exit input, shunts or unlocks door for programmed door unlock time, N/C loop or single EOL resistor supervision
    • ARM: arm input, permits arming by access card, N/C loop or single EOL resistor supervision
    • POST: autoarm postpone input, permits autoarm postponement by access card, N/C loop or single EOL resistor supervision
  • Current draw, 35mA (from Combus)


This product was added to our catalog on Friday December 05, 2008.


Other products you may be interested in:
RCI 4105 Fail Locked - UL Listed Door Strike, 1-1/8"x5-7/8", Centreline, Aluminum or Wood, 12V AC/DC
RCI 4105 Fail Locked - UL Listed Door Strike, 1-1/8"x5-7/8", Centreline, Aluminum or Wood, 12V AC/DC
RCI 7114 Fail Locked - UL Listed Door Strike, ANSI 1-1/4" x 4-7/8", Centreline, Metal, 12V DC
RCI 7114 Fail Locked - UL Listed Door Strike, ANSI 1-1/4" x 4-7/8", Centreline, Metal, 12V DC
RCI 4114 Fail Locked - UL Listed Door Strike, ANSI 1-1/4" x 4-7/8", Centreline, Metal, 24V AC/DC
RCI 4114 Fail Locked - UL Listed Door Strike, ANSI 1-1/4" x 4-7/8", Centreline, Metal, 24V AC/DC
HID 5365 MiniProx Reader
HID 5365 MiniProx Reader
DSC MAXSYS PC4020 16 Zone Control Panel with Can, Expandable to 128 Zones
DSC MAXSYS PC4020 16 Zone Control Panel with Can, Expandable to 128 Zones
Information
Shipping & Returns
Site Policies
Privacy Notice
Refurbished?
All Products
Contact Us
Shopping Cart more
0 items
Manufacturer Info
DSC
Other products
Currencies

Note: you must use Canadian currency if using an American Express credit card.

Copyright © 2003-2017 Electronic Product Online Ltd.
info@electronicproductonline.com
Products may not be exactly as shown.
Powered by osCommerce